|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
www..com SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. APPROVED DATE Approved For Specifications Approved For Specifications & Sample AMPIRE CO., LTD. 2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221, Taiwan (R.O.C.) 88 2 ( D ) TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270 APPROVED BY CHECKED BY ORGANIZED BY AM-1024600BTMQW-T00H BY Date : 2009/11/4 AMPIRE CO., LTD. 1 RECORD Revision Date 2009/4/3 2009/11/4 Page -4 15 Correct OF REVISION Contents www..com Editor Edward John New Release ABSOLUTE MAX. RATINGS & RELIABILITY TEST CONDITIONS Date : 2009/11/4 AMPIRE CO., LTD. 2 1. Features www..com 10 inch is Amorphous-TFT-LCD (Thin Film Transistor Liquid Crystal Display) module. This module is composed of a 10" TFT-LCD panel, a driving circuit and backlight system. This TFT LCD has a 10 (17:10) inch diagonally measured active display area with WSVGA (1024 horizontal by 600 vertical pixel) resolution. (1) (2) (3) (4) (5) (6) (7) (8) (9) Construction: 10" a-Si TFT active matrix, White LED Backlight and Touch Panel. Resolution (pixel): 1024(R.G.B) X600 Number of the Colors : 262K colors ( R , G , B 6 bit digital each) Display mode : Normally White Interface: One channel LVDS interface. Power Supply Voltage: 3.3V single power input. Build-in LED Driver IC. (5.0V Input Voltage). Viewing Direction: 6 O'clock. RoHS Compliance. 2. PHYSICAL SPECIFICATIONS Item LCD size Resolution Pixel pitch Active area Module size Surface treatment Color arrangement interface Weight Specifications 10 inch (Diagonal) 1024 x 3(RGB) x 600 0.21525(W) x 0.21525(H) 220.42(W) x 129.15(H) 235.0(W) x 145.8(H) x 7.2(D) Antiglare, Hard-Coating (3H) with EWV film RGB-stripe LVDS T.B.D (Typ) g dot mm mm mm unit Date : 2009/11/4 AMPIRE CO., LTD. 3 3. ABSOLUTE MAX. RATINGS Item Power voltage Operation temperature Storage temperature Symbol VLED VDD TOP TST Values Min. -0.3 -0.3 0 -20 Max. 6.0 6.0 50 60 www..com (GND = AVSS = 0V) UNIT V TFT Module Note 4. Mechanical Information Item Horizontal Module size Vertical Depth Min. 234.5 145.3 Typ. 235 145.8 5.5 Max. 235.5 146.3 5.8 UNIT mm mm mm 5. ELECTRICAL CHARACTERISTICS 5-1 Typical Operation Conditions Values Item Power voltage Power Supply Voltage For LED Current of power supply Note 1: VDD-dip condition : Symbol Min. VDD VLED IDD 3.0 4.7 Typ. 3.3 5.0 0.3 Max. 3.6 5.3 V V A VDD=3.3V Black pattern UNIT Note Note1 when 2.7VVDD<3.0Vtd10ms. VDD3.0VVDD-dip condition should be same as VDD-turn-con condition. Date : 2009/11/4 AMPIRE CO., LTD. 4 www..com 5-2 Switching Characteristics for LVDS Receiver Item Symbol Min. --100 -10 0.1 (|VID|/2) Typ. ----1.25 Max. 100 -+10 0.6 1.8-0.4-(|VID|/2) Unit mV mV uA V V Condition VCM=1.2V Differential Input High Threshold Differential Input Low Threshold Input current Differential input Voltage Common Mode Voltage Offset Vth Vtl IIN |VID| VCM 5-3 Bit Mapping & Interface Definition Date : 2009/11/4 AMPIRE CO., LTD. 5 www..com 6. Optical Specifications Values Item Symbol Condition Min. Typ. L R Viewing angle U D TR Response time TF Contrast ratio Color chromaticity WY Luminance Luminance uniformity L YU CR WX Normal ==0 -400 0.26 0.28 160 70 20 500 0.31 0.33 200 -28 -0.36 0.38 --msec ---cd/ % Note2 Note1 Note4 Note4 Note5 (CR10) 40 50 -50 60 5 --7 msec Note3 60 60 70 70 Max. --degree Unit Note Note1 Note2 6.1 Measuring surrounding dark room LED current : IL=200mA Ambient temperature252oC 15min. warm-up time. Date : 2009/11/4 AMPIRE CO., LTD. 6 www..com 6.2 Measuring Equipment The optical characteristics should be measured in dark room. After 30 minutes operation, the optical properties are measured at the center point of the LCD screen. (Response time is measured by Photo detector TOPCON BM-7 of view : 1 / Height : 120mm.) Note 1 : Definition of viewing angle range Note 2 : Definition of Contrast Ratio (CR) : measured at the center point of panel Luminance with all pixels white CR = ----------------------------------------------Luminance with all pixels black Date : 2009/11/4 AMPIRE CO., LTD. 7 www..com Note 3 : Definition of Response time : Sum of TR and TF Note 4 : Definition of optical measurement setup LCD Optical Detector Brightness gauge BM-7 (Topcon) LED LED:ON, LIGHT:OFF Note 5 : Definition of brightness uniformity Luminance uniformity = (Min Luminance of 9 points) ------------------------------------------------x100% (Max Luminance of 9 points) Date : 2009/11/4 AMPIRE CO., LTD. 8 7. INTERFACE TFT LCD Panel Driving Section Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Symbol GND VDD VDD V_EDID ADJ Ground 3.3V Power 3.3V Power 3.3V Power for EDID Adjust for LED brightness Description www..com Note Note* CLK_EDID EDID Clock Input DATA_EDID EDID Data Input RXIN0RXIN0+ GND RXIN1RXIN1+ GND RXIN2RXIN2+ GND LVDS Signal - channel0LVDS Signal+ channel0+ Ground Data Input channel1Data Input channel1+ Ground Data Input channel2Data Input channel2+ Ground RXCLKIN- Data Input CLKRXCLKIN+ Data Input CLK+ GND NC NC GND GND VLED VLED Ground NC NC Ground Ground VLED Power +5V VLED Power +5V Date : 2009/11/4 AMPIRE CO., LTD. 9 26 27 28 29 30 VLED NC NC NC NC VLED Power +5V NC NC NC NC www..com Note* : The brightness of LCD panel could be changed by adjusting ADJ (1)ADJ adjust brightness to control Pin. Pulse duty the bigger the brighter. Date : 2009/11/4 AMPIRE CO., LTD. 10 www..com 8. BLOCK DIAGRAM : TFT LCD Module Date : 2009/11/4 AMPIRE CO., LTD. 11 www..com 9. Touch Panel Electrical Specification Parameter Terminal Resistance Insulating Resistance Linearity Notes life by Pen Input life by finger Condition X Axis Y Axis DC 25 V -Note a Note b Standard Value 250 ~ 1200 100 ~ 600 More than 25M 1.5 % 50,000 times(min) 1,000,000 times (min) Note A . Notes area for pen notes life test is 10 x 9 mm. Size of word is 7.5 x 6.75 Shape of pen end : R0.8mm Load : 250 g Note B By Silicon rubber tapping at same point Shape of rubber end : R8mm Load : 200gf Frequency : 5 Hz Interface No. 1 2 3 4 Symbol Y2 X2 Y1 X1 Y2 X1 X2 Function Touch Panel Top Signal in Y Axis Touch Panel Right Signal in X Axis Touch Panel Bottom Signal in Y Axis Touch Panel Left Signal in X Axis Y1 4321 Date : 2009/11/4 AMPIRE CO., LTD. 12 www..com 10. Interface Timing (DE mode) Item Frame Rate Frame Period Vertical Display Time Vertical Blanking Time 1 Line Scanning Time Horizontal Display Time Horizontal Blanking Time Clock Rate Symbol Min. 55 612 600 12 1160 1024 136 39 Typ. 60 625 600 25 1200 1024 176 45 Max. 65 638 600 38 1240 1024 216 51.42 Unit Hz line line line clock clock clock MHz -t1 t2 t3 t4 t5 t6 t7 Timing Diagram of Interface Signal (DE mode) Date : 2009/11/4 AMPIRE CO., LTD. 13 10. Power On/Off Sequence www..com Item TP1 TP2 TP3 TP4 TP5 TP6 Note Min. 0.5 0 0 500 200 200 Typ. ------- Max. 10 50 50 ---- Unit msec msec msec msec msec msec Remark (1) The supply voltage of the external system for the module input should be the same as the definition of VDD. (2) Apply the lamp voltage within the LCD operation range. When the back-light turns on before the LCD operation or the LCD turns off before the back-light turns off, the display may momentarily become white. (3) In case of VDD = off level, please keep the level of input signal on the low or keep a high impedance. (4) TP4 should be measured after the module has been fully discharged between power off and on period. (5) Interface signal shall not be kept at high impedance when the power is on. Date : 2009/11/4 AMPIRE CO., LTD. 14 11. RELIABILITY TEST CONDITIONS Item High Temperature Storage Low Temperature Storage High Temperature Operation Low Temperature Operation Thermal Shock Shock Test Conditions Ta = 60 240 hrs www..com Note Ta = -20 240 hrs Ts = 50 240 hrs Ta = 0 240 hrs -20 /30 min ~ +60 /30 min 100 cycles Half-Sine, 200G, 2ms, XYZ, 1time Vibration Sine Wave 1.5G, 5~500Hz, XYZ 30min/each direction Storage / Operating temperature Note .Max wet bulb temp.=39oC Date : 2009/11/4 AMPIRE CO., LTD. 15 12. General Precautions 12.1 Use Restriction www..com This product is not authorized for use in life supporting systems, aircraft navigation control systems, military systems and any other application where performance failure could be life-threatening or otherwise catastrophic. 12.2 Disassembling or Modification Do not disassemble or modify the module. It may damage sensitive parts inside LCD module, and may cause scratches or dust on the display. Ampire does not warrant the module, if customers disassemble or modify the module. 12.3 Breakage of LCD Panel 12.3.1.If LCD panel is broken and liquid crystal spills out, do not ingest or inhale liquid crystal, and do not contact liquid crystal with skin. 12.3.2. If liquid crystal contacts mouth or eyes, rinse out with water immediately. 12.3.3. If liquid crystal contacts skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water. 12.3.4. Handle carefully with chips of glass that may cause injury, when the glass is broken. 12.4 Electric Shock 12.4.1. Disconnect power supply before handling LCD module. 12.4.2. Do not pull or fold the LED cable. 12.4.3. Do not touch the parts inside LCD modules and the fluorescent LED's connector or cables in order to prevent electric shock. 12.5 Absolute Maximum Ratings and Power Protection Circuit 12.5.1. Do not exceed the absolute maximum rating values, such as the supply voltage variation, input voltage variation, variation in parts' parameters, environmental temperature , etc., otherwise LCD module may be damaged. 12.5.2. Please do not leave LCD module in the environment of high humidity and high temperature for a long time. 12.5.3. It's recommended to employ protection circuit for power supply. Date : 2009/11/4 AMPIRE CO., LTD. 16 12.6 Operation www..com 12.6.1 Do not touch, push or rub the polarizer with anything harder than HB pencil lead. 12.6.2 Use fingerstalls of soft gloves in order to keep clean display quality, when persons handle the LCD module for incoming inspection or assembly. 12.6.3 When the surface is dusty, please wipe gently with absorbent cotton or other soft material. 12.6.4 Wipe off saliva or water drops as soon as possible. If saliva or water drops contact with polarizer for a long time, they may causes deformation or color fading. 12.6.5 When cleaning the adhesives, please use absorbent cotton wetted with a little petroleum benzine or other adequate solvent. 12.7 Mechanism Please mount LCD module by using mounting holes arranged in four corners tightly. 12.8 Static Electricity 12.8.1 Protection film must remove very slowly from the surface of LCD module to prevent from electrostatic occurrence. 12.8.2 Because LCD module use CMOS-IC on circuit board and TFT-LCD panel, it is very weak to electrostatic discharge. Please be careful with electrostatic discharge. Persons who handle the module should be grounded through adequate methods. 12.9 Strong Light Exposure The module shall not be exposed under strong light such as direct sunlight. Otherwise, display characteristics may be changed. 12.10 Disposal When disposing LCD module, obey the local environmental regulations. Date : 2009/11/4 AMPIRE CO., LTD. 17 13. OUTLINE DIMENSION www..com Date : 2009/11/4 AMPIRE CO., LTD. 18 14. EDID TABLE www..com Date : 2009/11/4 AMPIRE CO., LTD. 19 www..com Date : 2009/11/4 AMPIRE CO., LTD. 20 www..com Date : 2009/11/4 AMPIRE CO., LTD. 21 www..com Date : 2009/11/4 AMPIRE CO., LTD. 22 |
Price & Availability of AM-1024600BTMQW-T00H |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |